ASTM D2155: Autoignition Temperature

For more information Contact Us or visit our Home Page and Test Catalog

ASTM D2155 Autoignition Temperature of Liquid Chemicals

When heated, some materials can form vapors that react with atmospheric oxygen to spontaneously combust or autoignite – no ignition source is needed.  The lowest temperature at which this happens is the autoignition temperature (AIT). This test measures AITs up to 600ºC. There is a delay time between the sample reaching the AIT and combustion occurring. This is also determined in this test. A flask is heated to the test temperature. A small quantity of sample is injected into the flask and observed to see if ignition occurs. If it does not, the flask is cleaned and the process is repeated at a higher temperature.

When autoignition is observed, the temperature,  delay time and barometric pressure are reported.

ASTM E659 is a more modern method for determining autoignition temperatures.  It uses a diffiernt apparatus but gives similar results.

Price: $235.00

Sample size: 5 ml