PLTL-163 Storage Stability as per Mil-L-19701 – Oil Separation
Semi-fluid lubricants intended for aircraft usage, such as those used in power accessory equipment including machine guns, need to stay homogenous during storage. This test measures gross oil separation from the thickener phase in semi-fluid lubricants.
The semi-fluid is placed into a sample bottle and stored at the test temperature for the test time (50°C, 168 hours). It is then visually examined. A pass is reported if no oil layer has formed over the semi-fluid.
Price: $82.00
Sample size: 500 g
Related tests:
- ASTM D1742 – Oil Separation, Storage, of Greases @ 24 hours
- ASTM D1742 – Oil Separation, Storage, of Greases @ 48 hours
- ASTM D1742 – Oil Separation, Storage, of Greases @ 96 hours
- ASTM D1742 – Oil Separation, Storage, of Greases @ 168 hours
- ASTM D6184 – Oil Separation, Wire Cone Method
- DIN 51817 – Oil Separation Under Static Conditions @ 168 hours; one run for screening
- DIN 51817 – Oil Separation Under Static Conditions @ 18 hours; one run for screening
- GM 9030-P – Oil Separation, General Motors Specification